DJ & live sound

Check a microphone cable with a known working channel

Isolate a suspected cable without disturbing the whole stage patch.

DiGiCo S21 Mixing Console 2017

The short answer

Use a substitution test at low output level. A source, cable and input that are all unknown cannot identify a fault. Keep two known working parts while changing the third.

What to do

  1. Mute the affected channel and lower the relevant output
  2. Test the microphone on a known working compatible cable and input
  3. Return to the suspected cable while leaving source and input unchanged
  4. Label the suspect cable and remove it from show use if the fault follows it

Control connection noise

Follow the microphone and mixer instructions for phantom power and connection order. Do not repeatedly hot-plug into a loud PA. An intermittent fault may need a gentle movement test of the cable in normal use, without pulling connectors or bending them sharply.

Check the result

The fault should consistently follow one part of the chain, or remain unconfirmed and require further inspection.

Know the limits

This procedure does not test mains wiring. Never open powered equipment or bypass protective earth to diagnose noise.

Further reading

Sources for the connections and technical principles discussed above. The diagnostic sequences are our editorial explanation. Consult the manual for your exact model before changing hardware or settings.

These are general educational guides, not hands-on product reviews. How we prepare our content. Cover photo source & license.